• Hall Effect Device Based
  • Current Ratings up to 200A
  • Factory Programmable Current Range
  • Four Standard Current Ranges
  • Wideband DC to 200 kHz
  • Analog Output
  • Fast Response Time
  • 17 x 26 (mm) Footprint
  • Single 5V Supply
  • PCB Mounting

Applications

  • DC/AC Converters
  • DC/DC Converters
  • Battery Management
  • AC and DC Motor Drives
  • Welding Applications
  • Solar Applications

Part Number
Measurable Current Range
Output Slope
Accuracy
Linearity Error
Response Time
Sample Available
ISE-050-A-800
± 50 A
40.000 mV/A
≤ 0.6 %
≤ 0.1 %
3 uS
ISE-100-A-800
± 100 A
20.000 mV/A
≤ 0.6 %
≤ 0.1 %
3 uS
ISE-150-A-800
± 150 A
13.333 mV/A
≤ 0.6 %
≤ 0.1 %
3 uS
ISE-200-A-800
± 200 A
10.000 mV/A
≤ 0.6 %
≤ 0.1 %
3 uS
Part Number
ISE-050-A-800
ISE-100-A-800
ISE-150-A-800
ISE-200-A-800
  • GENERAL DATA

    Ambient Operating Temperature: -40 to +130 °C

    Ambient Storage Temperature: -40 to +130 °C

    Creepage Distance: 1.4 mm

    Clearance Distance: 1.4 mm

  • ABSOLUTE MAXIMUMS

    Over-Voltage Vdd Protection: +10 V

    Output Voltage Max: +10 V

    Output Current Max: +/- 70 mA

    Reverse Output Voltage Max: -0.3 V

    Reverse Output Current Max: -50 mA

NOTES:

All specifications at 25°C.

Specifications dependent on mechanical attachment.

Specifications are % full scale.

Output slope is dependent on Vdd.

Specifications above assumes 5 Vdd.

Specifications subject to change without prior notice.