• Higher Creepage
  • Faster Response Time
  • Small Size
  • Easy Busbar Mounting
  • UL Rated Lead Wire Connection
  • Factory Programmable
  • Customizable Current Range
  • Wideband DC to 200 kHz
  • Analog Output

Applications

  • DC/AC Converters
  • DC/DC Converters
  • Battery Management
  • AC and DC Motor Drives
  • Welding Applications
  • Solar Applications

Part Number
Measurable Current Range
Output Slope
Accuracy
Linearity Error
Response Time
Sample Available
ISB-100-A-802
± 100 A
20.000 mV/A
≤ 0.6 %
≤ 0.1 %
3 uS
ISB-175-A-802
± 175 A
11.429 mV/A
≤ 0.6 %
≤ 0.1 %
3 uS
ISB-300-A-802
± 300 A
6.667 mV/A
≤ 0.6 %
≤ 0.1 %
3 uS
ISB-425-A-802
± 425 A
4.706 mV/A
≤ 0.6 %
≤ 0.1 %
3 uS
ISB-550-A-802
± 550 A
3.636 mV/A
≤ 2.5 %
≤ 1.0 %
3 uS
ISB-670-A-802
± 670 A
2.985 mV/A
≤ 2.5 %
≤ 1.0 %
3 uS
Part Number
ISB-100-A-802
ISB-175-A-802
ISB-300-A-802
ISB-425-A-802
ISB-550-A-802
ISB-670-A-802
  • GENERAL DATA

    Ambient Operating Temperature: -40 to +105 °C

    Ambient Storage Temperature: -40 to +105°C

    RMS Voltage for AC Insulation: 4.3 kV

    Creepage Distance: >140 mm

    Clearance Distance: > 140 mm

  • ABSOLUTE MAXIMUMS

    Over-Voltage VDD Protection: +10 V

    Reverse VDD Protection: -10 V

    Output Voltage Max: +10 V

    Output Current Max: +/- 70 mA

    Reverse Output Voltage Max: -0.3 V

    Reverse Output Current Max: -50 mA

NOTES

All specifications at 25°C.

Specifications dependent on mechanical attachment.

Specifications are % full scale.

Output slope is dependent on Vdd. Specifications above assumes 5Vdd.

Vref = 50%Vdd +/- 1%

We recommend mounting the sensors with non-magnetic screws for maximum accuracy. We recommend stainless steel, brass, bronze, copper or aluminum.